Single-phase 200 V to three-phase 200 V
Three-phase converter

Input a single-phase 200V and output a sine wave of three-phase three-line 200V and 50/60Hz.

Used by multiple public institutions in Japan

Three-phase converter INV-9600PTV to convert single-phase 200V to three-phase 200V
Single phase 200V → Three phase 200V

Three-phase converter
Product Lineup

The INV-9600PTV supplies three-phase 200 V sine-wave power from single-phase 200 V or a DC source such as a battery. It can power three-phase motors, pumps, compressors and commercial air conditioners at factories, business premises and construction sites without three-phase utility service.

Three Phase Converter Specifications Comparison
SpecificationINV-9600PTVINV-12000PTVINV-24000PTV
Output FormatThree-phase three-wire 200V, 50/60Hz, sine waveThree-phase three-wire 200V, 50/60Hz, sine waveThree-phase three-wire 200V, 50/60Hz, sine wave
Output PowerMax 9.6kVAUp to 12kVAMax 24kVA
Input format1Single phase 200V 50/60HzSingle phase 200V 50/60HzSingle phase 200V 50/60Hz
Input format 2DC 19V〜66VDC 19V〜66VDC 19V〜66V
Main body dimensions640 × 717 × 709 mm640 × 717 × 709 mm640 × 717 × 1350 mm
Weight100kg110kg215kg
We have 3 models up to 24kVA.

Example of conversion and utilization of single-phase 200V to three-phase 200V

1 Convert 200V of single phase to 200V of three phase

  1. Run an elevator requiring three-phase power from a single-phase 200 V source.
  2. In a large factory, convert a nearby single-phase 200 V circuit rather than extending wiring from a distant three-phase distribution board.
  3. Three-phase 200V power supply is available at a rental factory without three-phase power supply.
  4. Demonstration of three-phase motors and power devices at exhibition halls.

2 Convert DC power sources such as batteries to three-phase 200V

  1. Run a submersible pump from battery storage.
  2. Drive air compressor from electric forklift battery.
  3. Combine the converter with LFP batteries for emergency power for machine tools.

How to convert a single-phase 200V to three-phase 200V

Workshops and factories may need to run three-phase 200 V motors, pumps or compressors where only single-phase 200 V is available. The INV-9600PTV accepts single-phase 200 V and supplies three-phase, three-wire 200 V sine-wave power at 50/60 Hz.

Three-phase power supply is difficult

Rented workshops, temporary installations, exhibition halls and construction sites can use an existing single-phase 200 V supply where a new three-phase service or extensive rewiring is impractical. Applications include motor operation, machinery relocation and temporary three-phase power.

What three-phase devices can be used?

Applications include three-phase 200 V motors, pumps, compressors, machine tools, conveyors, farm machinery, test equipment and commercial air conditioners. For compressors and machine tools on single-phase 200 V, verify the equipment specifications. Suitability depends on starting power and load characteristics as well as rated capacity.

Selection of capacity

Three-phase equipment can require considerably more power at startup than in operation. Check rated voltage, rated current, capacity and starting method. The INV-9600PTV supplies up to 9.6 kVA; custom units are available up to 24 kVA.

Three Phase 200V Power Supply Issues and Application Guide

We will show you the comparison between the method of securing power supply, the starting condition of the equipment, and the construction according to the problems of factory and machine installation without three-phase power supply.

Phase converter FAQs

Can I make a three-phase 200V from a single-phase 200V?

Yes. INV-9600PTV inputs a single phase 200V and outputs a three-phase three-wire 200V and 50/60Hz sine wave power supply. This is the option to convert a single phase 200V to a three-phase 200V with a factory or temporary facility that does not have a three-phase power supply.

Can I use it for three phase motors?

Yes, for compatible three-phase 200 V motors. Check the motor rating, starting method and mechanical load before selecting the required capacity.

Is it possible to output a three-phase 200V from the battery?

Yes. INV-9600PTV supports DC 19V to 66V DC input, and can output three-phase 200V from DC power supply such as battery to meet the requirements.

Specification sheet

INV-9600PTV Three Phase Converter

Open the specification sheet (PDF, Japanese) →

Economy single-phase to three-phase converters (modified sine wave)

These converters directly drive the motor in equipment such as pumps and compressors.
The output is not a sine wave and must not be used to supply associated control circuits.

Three-phase converter
(modified sine wave)
Series
Target load capacity
Motor Pump
Compressors
ModelInputOutput
(modified sine wave)
Main body dimensions
W×H×D(mm)
Weight
INV-750PTUp to 0.75 kWINV-750PT-100Single phase 100V
(50/60Hz)
Three Phase 200V
(selectable 50/60 Hz)
300 × 300 × 2004.0kg
INV-750PT-200Single phase 200V
(50/60Hz)
INV-3700PT3.7kW or lessINV-3700PTSingle phase 200V
(50/60Hz)
Three Phase 200V
(selectable 50/60 Hz)
400 × 600 × 2309.0kg

Inquiries about Three Phase 200V Power Supply

If you are considering converting a single phase from 200V to 200V, please let us know the type of device you use, the rated voltage, the rated current, the starting method, and the conditions of the available single phase 200V power supply.

E-mail:info@variostor.com

Tel:087-862-5518