How to use a three-phase 200V machine tool in a single-phase 200V field

Measures to prevent the three-phase power supply in the purchase of used lathe, milling machine, and drilling machine and factory transfer.

This is a technical guide to consider the feasible method from the conditions of site registration and the specifications of the equipment used. It does not guarantee the conformity of the equipment only with the description.

Check the power supply before purchasing a used machine

Even a working used lathe or mill cannot run immediately if its new site lacks three-phase 200 V. Check the entire machine, including the spindle motor, feed drives, hydraulic and coolant pumps, controls and lighting.

  • Voltage, frequency, rated current, total power supply capacity of machine name plates
  • Number of spindles and auxiliary motors, or simultaneous operation
  • Supply requirements and connection points for control circuits and transformers
  • Peak current at startup, start order, driving cycle

How to make a single-phase 200V to three-phase 200V

Output three-phase 200V from a single-phase 200V power supply that meets the requirements if it is difficult to draw three-phase to a power company Three-phase converter It is possible to consider. However, a single-phase circuit requires sufficient supply capacity. In addition, some cases may not be available depending on the specifications and manufacturer requirements of the machine tool.

The general-purpose inverter for motors is mainly used for motor rotation speed control. It is not possible to connect to the whole machine tool, including multiple motors and control circuits, as it is, instead of commercial three-phase power supply.Differences per method Please check it out.

Point of choice of converter

It is not recommended to select 5.5 kVA power supply by looking at the output value of "5.5 kW" of the motor. Consider including efficiency, power factor, starting load and auxiliary equipment.

Our Company INV-9600PTV The single-phase 200V input, three-phase three-wire 200V sine wave output is up to 9.6kVA. The model of 12kVA and 24kVA is also introduced, but it is not possible to determine conformity only with the number of capacity.

Checklist before introduction

  1. Specify the model, nameplate photo and instruction manual of the machine
  2. Check the power capacity of the entire machine, the maximum starting load
  3. Check the distribution board’s single-phase 200 V circuit, contracted capacity and breaker rating.
  4. Check the power supply quality, grounding and protection conditions required by the manufacturer
  5. Plan wiring and safety confirmation by qualified personnel

For remodeling and wiring of existing machines, please check with the machine manufacturer and specialized in electrical work.

Please contact us for 3-phase 200V power supply.

Please let us know the type, nameplate photo and start method of the machine and the conditions of the single-phase 200V power supply available on site. We will check the compatibility and capacity selection.