It is a guide to organize the specifications and power supply conditions of the equipment. Actual conformity is determined by confirming the model and site conditions.
4 items to confirm first
- Motor nameplate:Check rated voltage, current, output (kW), frequency (50/60Hz).
- Start method: Check whether it is a direct start or a configuration that suppresses the start current with an inverter.
- Load of machine:The load on the operation and start of the pump or compressor differs depending on the air rolling.
- Single-phase input supply: Check the contract capacity, circuit and circuit breaker and wiring length of the switchboard.
Only motor kW can not be determined
A motor marking such as 2.2 kW does not directly indicate converter input demand. Starting current, mechanical load and simultaneous controls affect the required capacity. Converter ratings are in kVA: comparing kW figures alone cannot establish suitability.
In particular, short-time current may increase in the direct start. In addition to the motor, the specification of the control panel and electromagnetic contactor is also confirmed in the existing machine.
INV-9600PTV
Our Company 3-phase converter INV-9600PTV The maximum output is 9.6kVA, with a single-phase 200V to three-phase 200V and 50/60Hz output.
If you want to use multiple motors in machine tools and conveying equipment, please share all simultaneous operation loads and start order.
Useful information when contacting us
- Motor Name Plate Photo and Machine Whole Name Plate
- The current start method and the order to start
- Single-phase 200V power supply circuit capacity, installation place
- Continuous operating time and other simultaneous loads
To select and install wiring and protective equipment, please ask a qualified person who has confirmed the site conditions.
Please contact us from the type of equipment.
If you have a nameplate photo and a single-phase 200V power supply that can be used, you can organize your confirmation.