Three-phase inverter is a power supply that converts DC power to three-phase AC (AC). Vario Electric enters DC24V/DC48V and introduces 12kW class products that output three-phase 200V.
Three Phase Inverter
This is a three-phase inverter that converts DC power to three-phase 200V. It can be used as a driving power supply such as motor and commercial air conditioner with a three-phase three-line pure sine wave output.
- Input: DC24V / DC48V
- Output: Three-phase 3-wire 200V
- Pure sine wave, 50/60Hz switch
- Compatible with 5.5kW motors, industrial air conditioners, etc.
| DC/AC Inverter | Input Voltage | Maximum output | Output voltage | Output Frequency | Output waveform | Outline dimension (L×W×H) | Weight |
|---|---|---|---|---|---|---|---|
| INV-4000PS-TP12K 12kW class ![]() ![]() ![]() | DC24V (19〜33V) | 12kW Instant maximum 16.8kW (10sec) | Three-phase three-wire 200V Power supply | 50/60Hz | Pure Sine Wave | 460×211×84mm × 3 units | 10.5kg × 3 units |
| DC48V (38〜66V) | 12kW Instant maximum 16.8kW (10sec) | Three-phase three-wire 200V Power supply | 50/60Hz | Pure Sine Wave | 460×211×84mm × 3 units | 10.5kg × 3 units |
Three Phase Inverter Applications
This is the option to secure the power supply of three-phase 200V devices in the field where the direct current power supply such as the battery is only available.
- Three-phase 200V motor and pump drive power supply
- Securing three-phase power supply in construction sites and temporary equipment
- Independent power supply and emergency power supply system combined with battery
- Review of three-phase equipment such as commercial air conditioners
Example: Three-phase air conditioner was operated using this three-phase inverter to power the DC48V battery.
The actual equipment depends on the requirements of starting current, load conditions, control power supply and power supply quality. It does not guarantee the operation of all three-phase devices.
How to choose a three-phase inverter to make a three-phase 200V from DC48V and DC24V
Unlike a motor speed controller, this inverter accepts DC from a battery or other DC source and supplies three-phase, three-wire 200 V AC with a pure sine wave at 50/60 Hz. When selecting a power source for machinery or backup service, check both the battery and the connected load.
| Input Power | Supported input range | Approximate input current at 12kW output |
|---|---|---|
| DC24V | DC19〜33V | Approx. 500 A at 24 V, excluding losses |
| DC48V | DC38〜66V | Approx. 250 A at 48 V, excluding losses |
These theoretical estimates use P/V. Actual current varies with efficiency, battery voltage and load power factor. Do not use these figures alone to size DC wiring or protection devices.
Expected Use
- Power supply from battery to pump and industrial machine with three-phase 200V
- Maintain three-phase power during outages for business continuity
- Studying the structure of the facility with a temporary facility without three-phase power transmission
If single-phase AC200V is input power supply,Single Phase 200V Input Three Phase Converter Please check the difference between the input method and select the product.
Difference between three-phase inverter and motor control inverter
The three-phase inverter is also referred to as the three-phase inverter. The general inverter is mainly used to control the motor rotation speed and start. On the other hand, the DC-AC inverter outputs the three-phase three-wire 200V pure sine wave power supply from the DC power supply to 50/60Hz.
Before powering a complete machine, check its control panel, protective circuits and the manufacturer’s supply requirements.Comparison of single-phase 200V to three-phase 200V Please refer to this page.
Check before introduction
- Battery voltage range, continuous discharge capacity, wiring and protection equipment
- Three-phase equipment rated voltage, rated current, starting method, maximum load
- Number of simultaneous operation equipment, operation time, start order
- Ambient temperature, ventilation, installation space, safety and ground conditions
For example, when supplying 12kW from a DC48V system, the input current reaches 250A even if the conversion loss is ignored. Actually, the design of the DC wiring, protection and storage battery is important because there is a loss or voltage drop. Please consult a qualified specialist for the design and construction of electrical equipment.
Frequently asked questions
Is it possible to output three-phase 200V from a DC48V battery?
This is an input specification of the DC48V system (38~66V). Please check not only the voltage range of the battery, but also the required discharge current and protection conditions.
Can I convert a single-phase 200V to a three-phase 200V?
This model accepts DC only. For a single-phase 200 V input, see the Three-phase converter for single-phase 200V input for details.
Can I use a 5.5kW motor?
It is not possible to determine the capacity of the motor only. We will consider conformance after confirming the thrust current and the load condition of the machine side at the time of direct start.
Inquiry about Three Phase Inverter
Please let us know the input power supply (DC24V/DC48V), the model and nameplate of the three-phase device to be used, the load capacity, the start method, and the operation time. We will guide you to the necessary power supply configuration.